Guides

How do you read a window's energy label and sound ratings?

By Pergo Systems · Updated November 16, 2026.

The NFRC label on a window or patio door gives independently verified ratings for the whole unit: U-factor (heat loss; lower is better), solar heat gain coefficient (the sun's heat; lower lets in less) and visible transmittance (daylight). Sound ratings, STC and OITC, come from a lab test of one sample and do not promise the result in your room.

Free in-home consultationCA Lic. #1150406 (C-17 Glazing)Consultations take place at your property
01

The three numbers on every NFRC label

  • U-factor (top left). How easily heat passes through the whole window or door. A lower number means less heat escapes; in warm weather a low U-factor also cuts the need for cooling.
  • Solar heat gain coefficient, SHGC (top right). The share of the sun's heat that comes through, on a scale from 0 to 1. A lower number lets in less heat. In a warm climate a low SHGC matters most on east, south and west walls; north windows get little direct sun.
  • Visible transmittance, VT. How much daylight comes through, from 0 to 1. A higher number means more daylight. Coatings on the glass can keep out heat and still let in light, so read VT next to SHGC.
  • Whole unit, not the glass alone. The numbers include the frame. Compare whole-unit figures, not center-of-glass ones.
02

Two numbers the label may show

  • Air leakage. How much outside air gets through the unit. A lower number means less air gets in. It is optional on the label.
  • Condensation resistance. A score from 1 to 100; a higher score means moisture is less likely to form on the inside of the glass. Also optional, and most useful in cold, damp weather.
03

What the label does not tell you

  • How it was installed. NFRC's ratings do not take the installation into account. A well-made window installed badly can still leak air.
  • How your exact window will do. The ratings are set for a fixed set of test conditions and one set product size. Use them to compare one window with another, not to forecast your bills.
  • How much noise it blocks. NFRC does not rate windows for sound. Sound ratings come from a separate lab test, explained below.
  • Keep the label. NFRC says a window without its label is not treated as an NFRC-rated window, and a label cannot be sent on its own later. ENERGY STAR advises keeping the labels as your record.
04

ENERGY STAR and California's energy code

  • ENERGY STAR. A window, door or skylight with the ENERGY STAR label is made by an ENERGY STAR partner, rated by NFRC, and has NFRC numbers within the limits the EPA sets for the climate zones shown on that label. Doors are judged by how much glass they have. The current limits took effect October 23, 2023. ENERGY STAR uses its own climate zones, not California's 16.
  • California's code. A replacement window must also meet the state energy code. Permits applied for from January 1, 2026 follow the 2025 code. The Energy Commission's manual lists, for replacement windows on the code's checklist path, a U-factor of 0.27 or lower in climate zones 1 to 5, 11 to 14 and 16, and an SHGC of 0.23 or lower in zones 2, 4 and 6 to 15. A job with up to 75 square feet of replacement windows may use a U-factor of 0.40 and, where an SHGC limit applies, 0.35 instead. Small homes and a few other cases have their own figures, so check your zone and project with the city. Both numbers are read from the NFRC label.
05

What STC and OITC measure

  • STC (sound transmission class). One number, worked out under ASTM E413 from a lab test under ASTM E90 of how much sound a sample stops. ASTM says it follows speech, radio and TV noise in a general way, and does not suit traffic, aircraft, trains or music.
  • OITC (outdoor-indoor transmission class). One number, worked out under ASTM E1332, for outdoor road, rail and air traffic noise, which carries strong low tones. A sample needs to stop a lot of low sound to rate high. For that kind of noise, ASTM says OITC ranks windows more reliably than STC.
  • Compare like with like. STC with STC and OITC with OITC, for the same size and the same glass. ASTM advises using the full test data, not one number, for a final choice.
06

Why a lab sound rating is not a promise for your room

STC and OITC are measured on one sample in a lab built so that the sample is the only real path for sound. A home has other paths: walls, vents, gaps, doors and other windows. ASTM says lab ratings do not translate directly into how well a finished building keeps sound out; they are an upper limit on what a test in a building would find. So a lab sound rating does not promise the result in your room. Gaps matter too: NFRC notes that sound and air pass through the same leaks, so how the window is sealed into the wall counts.

Questions

Questions people ask about window labels

What is a good U-factor?

It depends on your climate and the code. For a replacement window in California under the 2025 code, the Energy Commission's figure is 0.27 or lower in climate zones 1 to 5, 11 to 14 and 16. Lower keeps more heat in.

Should I pick the lowest SHGC I can find?

Not on every wall. In a warm climate a low SHGC helps most on east, south and west walls; north windows get little direct sun. Read VT as well, so the room keeps its daylight.

Will a window with a higher STC make my room quieter?

Not always. The sample stopped more sound in the lab, but your walls, vents, gaps and other openings also let noise in, and STC does not suit traffic noise. For traffic, compare OITC for the same size and glass.

Why is there no sound rating on the label?

NFRC does not rate windows for sound. STC and OITC come from a separate lab test report for a tested sample; ask which size and glass were tested.

Does an ENERGY STAR label mean the window meets California's code?

Not by itself. ENERGY STAR uses its own climate zones and limits. Check the U-factor and SHGC on the NFRC label against the code for your zone.

Free in-home consultation

Get a written plan for your home.

A specialist visits, looks at every opening and gives you a written proposal. Or call (844) 790-3600.

Book a free in-home consultation